Unit of Measure
Items
Image

Ex9CS/C Series Mechanical Interlock
BOM

Image

Ex9CS/C Series Mechanical Interlock
BOM

Image

Ex9CS/C Series Mechanical Interlock
BOM

Image

Ex9CS/C Series Mechanical Interlock
BOM

Image

Ex9CS/C Series Mechanical Interlock
BOM
Description N/A
Brands N/A NOARK®
Certifications N/A
  • UL 508 Listed File Number E3553866 / UL 60947-1 and 60947-4-1
  • Certified for Canada according to CSA C22.2 No. 14
  • IEC/EN 60947-4-1
  • CE approved
  • CCC Certified
  • RoHS Compliant
N/A
  • UL 508 Listed File Number E3553866 / UL 60947-1 and 60947-4-1
  • Certified for Canada according to CSA C22.2 No. 14
  • IEC/EN 60947-4-1
  • CE approved
  • CCC Certified
  • RoHS Compliant
N/A
  • UL 508 Listed File Number E3553866 / UL 60947-1 and 60947-4-1
  • Certified for Canada according to CSA C22.2 No. 14
  • IEC/EN 60947-4-1
  • CE approved
  • CCC Certified
  • RoHS Compliant
N/A
  • UL 508 Listed File Number E3553866 / UL 60947-1 and 60947-4-1
  • Certified for Canada according to CSA C22.2 No. 14
  • IEC/EN 60947-4-1
  • CE approved
  • CCC Certified
  • RoHS Compliant
N/A
  • UL 508 Listed File Number E3553866 / UL 60947-1 and 60947-4-1
  • Certified for Canada according to CSA C22.2 No. 14
  • IEC/EN 60947-4-1
  • CE approved
  • CCC Certified
  • RoHS Compliant
Features N/A MIT41 cannot be installed by end user. N/A Ex9C contactors are intended for various applications including heavy industrial ones. Splitting into four frame sizes brings optimization of electrical parameters and mechanical dimensions. All these frame sizes share accessory auxiliary contacts. Overload relays differ with the frame sizes in order to fit respective contactor of given rated current.
  • Contactors according to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1and UL 60947-4-1
  • Nine frame sizes with rated current up to 1000 A at 690 V AC-3
  • Coil control voltage 24~600 Vac, 24~250 Vdc; 24~600 Vac/dc (115~300 A); 36~600 Vac/dc (400~500 A)
  • Wide range electronic coil available for 09~500 A contactor
  • Mounts onto DIN rail 35 mm or 75 mm or onto panel (frame sizes 09~38 mount on 35 mm; 40~100 mount on 35 mm or 75 mm; 115~1000 cannot be mount on DIN rail, only mount by screw)
N/A Ex9C contactors are intended for various applications including heavy industrial ones. Splitting into four frame sizes brings optimization of electrical parameters and mechanical dimensions. All these frame sizes share accessory auxiliary contacts. Overload relays differ with the frame sizes in order to fit respective contactor of given rated current.
  • Contactors according to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1and UL 60947-4-1
  • Nine frame sizes with rated current up to 1000 A at 690 V AC-3
  • Coil control voltage 24~600 Vac, 24~250 Vdc; 24~600 Vac/dc (115~300 A); 36~600 Vac/dc (400~500 A)
  • Wide range electronic coil available for 09~500 A contactor
  • Mounts onto DIN rail 35 mm or 75 mm or onto panel (frame sizes 09~38 mount on 35 mm; 40~100 mount on 35 mm or 75 mm; 115~1000 cannot be mount on DIN rail, only mount by screw)
N/A Ex9C contactors are intended for various applications including heavy industrial ones. Splitting into four frame sizes brings optimization of electrical parameters and mechanical dimensions. All these frame sizes share accessory auxiliary contacts. Overload relays differ with the frame sizes in order to fit respective contactor of given rated current.
  • Contactors according to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1and UL 60947-4-1
  • Nine frame sizes with rated current up to 1000 A at 690 V AC-3
  • Coil control voltage 24~600 Vac, 24~250 Vdc; 24~600 Vac/dc (115~300 A); 36~600 Vac/dc (400~500 A)
  • Wide range electronic coil available for 09~500 A contactor
  • Mounts onto DIN rail 35 mm or 75 mm or onto panel (frame sizes 09~38 mount on 35 mm; 40~100 mount on 35 mm or 75 mm; 115~1000 cannot be mount on DIN rail, only mount by screw)
N/A Ex9C contactors are intended for various applications including heavy industrial ones. Splitting into four frame sizes brings optimization of electrical parameters and mechanical dimensions. All these frame sizes share accessory auxiliary contacts. Overload relays differ with the frame sizes in order to fit respective contactor of given rated current.
  • Contactors according to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1and UL 60947-4-1
  • Nine frame sizes with rated current up to 1000 A at 690 V AC-3
  • Coil control voltage 24~600 Vac, 24~250 Vdc; 24~600 Vac/dc (115~300 A); 36~600 Vac/dc (400~500 A)
  • Wide range electronic coil available for 09~500 A contactor
  • Mounts onto DIN rail 35 mm or 75 mm or onto panel (frame sizes 09~38 mount on 35 mm; 40~100 mount on 35 mm or 75 mm; 115~1000 cannot be mount on DIN rail, only mount by screw)
Note N/A MIT41 cannot be installed by end user. N/A N/A N/A N/A