Ex9M1PV (15A to 100A) Molded Case Circuit Breakers - 1000VDC
Molded Case Circuit Breakers
NOARK® Electric M1PV Series molded case breaker are 1000Vdc rated and offer ampacities from 15A to 100A. Rated at 10kA to 1000Vdc, these breakers offer a solution for Solar PV and Electric Vehicke Charging applications. Like all NOARK® products, the M1PV is backed by our 5-year limited warranty..
Unit of Measure
| Items |
/Asset/NOA-M1PVS15T3LA---1102471_face.jpg M1PVS15T3A M1PVS Series Connection A - 3 Poles, 15 Ampere (A) Rated Current Fixed Thermal and Fixed Magnetic Molded Case Circuit Breaker |
/Asset/NOA-M1PVS15T3LA---1102471_face.jpg M1PVS20T3A M1PVS Series Connection A - 3 Poles, 20 Ampere (A) Rated Current Fixed Thermal and Fixed Magnetic Molded Case Circuit Breaker |
/Asset/NOA-M1PVS15T3LA---1102471_face.jpg M1PVS25T3A M1PVS Series Connection A - 3 Poles, 25 Ampere (A) Rated Current Fixed Thermal and Fixed Magnetic Molded Case Circuit Breaker |
/Asset/NOA-M1PVS15T3LA---1102471_face.jpg M1PVS30T3A M1PVS Series Connection A - 3 Poles, 30 Ampere (A) Rated Current Fixed Thermal and Fixed Magnetic Molded Case Circuit Breaker |
/Asset/NOA-M1PVS15T3LA---1102471_face.jpg M1PVS35T3A M1PVS Series Connection A - 3 Poles, 35 Ampere (A) Rated Current Fixed Thermal and Fixed Magnetic Molded Case Circuit Breaker |
|||||
| Description |
N/A
M1 Frame 15~100 A (1000 Vdc MCCB) The NOARK® Electric M1PVS is a UL489B DC Molded Case Circuit Breaker available in current ratings of 15A to 100A with a breaking capacity of 10kA at 1000 Vdc. Each unit is equipped with thermal magnetic trip units for protection of overload and short circuit in photovoltaic system. The M1PVS features a poles-in-series design and is equipped with pre-installed jumpers. Four jumper connection configurations are offered for grounded and ungrounded systems. Like all NOARK® Electric products, the M1PVS is backed by a 5-year limited warranty. |
|||||||||
| Brands | N/A NOARK® | |||||||||
| Rated Current at 1000 Volt (V) Alternating Current (AC) Voltage | N/A 10 kA | |||||||||
| Rated Current | N/A 15 A | N/A 20 A | N/A 25 A | N/A 30 A | N/A 35 A | |||||
| Connection Type | N/A Bus Bar Connection | |||||||||
| Number of Poles | N/A 3 | |||||||||
| Direct Current (DC) Rated Service Voltage | N/A 1000 V | |||||||||
| Trip Unit | N/A TM | |||||||||
| Ambient Temperature | N/A -20 to 50 ºC | |||||||||
| Mechanical Life | N/A 10,000 cycles | |||||||||
| Electrical Life (Operations at 1000 Direct Current (DC) Voltage) | N/A 1,000 cycles | |||||||||
| Width | N/A 3.5 in90 mm | |||||||||
| Depth | N/A 3.33 in84 mm | |||||||||
| Height | N/A 7.91 in201 mm | |||||||||
| Weight (With Jumper) | N/A 1.50 kg3.29 lb | |||||||||
| Suitable for Reverse-Feed Applications | N/A true | |||||||||
| Terminations |
N/A
Connections - Jumpers Cable Selection - CU |
|||||||||
| Certifications |
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
|||||
| Accessories |
N/A
|
N/A
Alarm Switch Auxiliary Contact Shunt Trip Under-Voltage Trip Handle Lock Flange Handle Rotary Handle Mechanical Interlock Motor Operator |
N/A
Alarm Switch Auxiliary Contact Shunt Trip Under-Voltage Trip Handle Lock Flange Handle Rotary Handle Mechanical Interlock Motor Operator |
N/A
Alarm Switch Auxiliary Contact Shunt Trip Under-Voltage Trip Handle Lock Flange Handle Rotary Handle Mechanical Interlock Motor Operator |
N/A
Alarm Switch Auxiliary Contact Shunt Trip Under-Voltage Trip Handle Lock Flange Handle Rotary Handle Mechanical Interlock Motor Operator |
|||||
| Features |
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
|||||
|
|
||||||||||