Ex9M2 (100A to 250A) Molded Case Circuit Breakers
Molded Case Circuit Breakers
NOARK® Electric Molded Case Circuit Breakers Ex9M2 Series:
- UL 489 Listed, File Number E35539
- CSA Standards 22.2 No.5 File Number E355392
- 100A to 250A Ratings
- 480VAC, 250VDC Maximum (1P)
- 600VAC, 600VDC Maximum (2P, 3P)
- 1 Pole, 2 Pole, 3 Pole
- UL 489 Listed, File Number E35539
- CSA Standards 22.2 No.5 File Number E355392
- 100A to 250A Ratings
- 480VAC, 250VDC Maximum (1P)
- 600VAC, 600VDC Maximum (2P, 3P)
- 1 Pole, 2 Pole, 3 Pole
Interrupting Ratings: | |||
Ex9M2N (1P) | Ex9M2S (2P, 3P) | Ex9M2N (2P, 3P) | Ex9M2H (2P, 3P) |
50kAIC at 240VAC | 50kAIC at 240VAC | 100kAIC at 240VAC | 150kAIC at 240VAC |
10kAIC at 480VA | 35kAIC at 480Vac | 65kAIC at 480VAC | 100kAIC at 480VAC |
14kAIC at 600VAC | 20kAIC at 600VAC | 25kAIC at 600VAC |
Unit of Measure
Items |
/Asset/a1123.jpg M2S100T22 Ex9M2S Series MCCB; Thermal-Magnetic Trip Unit |
/Asset/a1123.jpg M2S125T22 Ex9M2S Series MCCB; Thermal-Magnetic Trip Unit |
/Asset/a1123.jpg M2S150T22 Ex9M2S Series MCCB; Thermal-Magnetic Trip Unit |
/Asset/a1123.jpg M2S175T22 Ex9M2S Series MCCB; Thermal-Magnetic Trip Unit |
/Asset/a1123.jpg M2S200T22 Ex9M2S Series MCCB; Thermal-Magnetic Trip Unit |
|||||
Rated Current | N/A 100 A | N/A 125 A | N/A 150 A | N/A 175 A | N/A 200 A | |||||
Number of Poles | N/A 2 | |||||||||
IC Class |
N/A S | |||||||||
Interrupting Capacity |
N/A
50kA at 240Vac 35kA at 480Vac 14kA at 600Vac 20kA at 500Vdc |
|||||||||
Termination Type | N/A Bus Bar Type | |||||||||
Terminal Specification | N/A Bus Bar Type | |||||||||
Note |
N/A
Special Order Item. Line/Load Lug type breakers can be converted to busbar connection type. |
N/A
Special Order Item. Line/Load Lug type breakers can be converted to busbar connection type. |
N/A
Special Order Item. Line/Load Lug type breakers can be converted to busbar connection type. |
N/A
Special Order Item. Line/Load Lug type breakers can be converted to busbar connection type. |
N/A
Special Order Item. Line/Load Lug type breakers can be converted to busbar connection type. |
|||||
Features |
N/A
|
|||||||||
Certifications |
N/A
|
|||||||||
UL Certificate |
N/A
Ex9 Series M2 Bus Bar and Lug Line/Load Side Connection Molded Case Circuit Breakers (NOA_M2_UL Certificate) |
|||||||||
Description |
N/A
100A - M2S Busbar Connection; 2 Poles; Adjustable Thermal and Adjustable Magnetic, MCCB |
N/A
125A - M2S Busbar Connection; 2 Poles; Adjustable Thermal and Adjustable Magnetic, MCCB |
N/A
150A - M2S Busbar Connection; 2 Poles; Adjustable Thermal and Adjustable Magnetic, MCCB |
N/A
175A - M2S Busbar Connection; 2 Poles; Adjustable Thermal and Adjustable Magnetic, MCCB |
N/A
200A - M2S Busbar Connection; 2 Poles; Adjustable Thermal and Adjustable Magnetic, MCCB |
|||||
|