NOARK® Electric Molded Case Circuit Breakers Ex9M5 Series:
- UL 489 Listed, File Number E35539
- CSA Standards 22.2 No.5 File Number E355392
- 600A to 800A Ratings
- 600VAC, 600VDC Maximum
- 2 Pole, 3 Pole, 4 Pole
  Interrupting Ratings:
  Ex9M5S Ex9M5N Ex9M5H
  65kAIC at 240VAC 100kAIC at 240VAC 150kAIC at 240VAC
  42kAIC at 480Vac 65kAIC at 480VAC 100kAIC at 480VAC
  22kAIC at 600VAC 30kAIC at 600VAC 50kAIC at 600VAC
Items
Ex9 Series M5 Bus Bar and Lug Line/Load Side Connection Molded Case Circuit Breakers

Ex9M5S Series MCCB; Thermal-Magnetic Trip Unit
BOM

Ex9 Series M5 Bus Bar and Lug Line/Load Side Connection Molded Case Circuit Breakers

Ex9M5S Series MCCB; Thermal-Magnetic Trip Unit
BOM

Ex9 Series M5 Bus Bar and Lug Line/Load Side Connection Molded Case Circuit Breakers

Ex9M5S Series MCCB; Thermal-Magnetic Trip Unit
BOM

Ex9 Series M5 Bus Bar and Lug Line/Load Side Connection Molded Case Circuit Breakers

Ex9M5S Series MCCB; Thermal-Magnetic Trip Unit
BOM

Ex9 Series M5 Bus Bar and Lug Line/Load Side Connection Molded Case Circuit Breakers

Ex9M5S Series MCCB; Thermal-Magnetic Trip Unit
BOM
Rated Current N/A 600 A N/A 700 A N/A 800 A N/A 600 A N/A 700 A
Number of Poles N/A 2 N/A 2 N/A 2 N/A 3 N/A 3
IC Class
N/A S
Interrupting Capacity N/A 65kA at 240Vac
42kA at 480Vac
22kA at 600Vac
Termination Type N/A Bus Bar Type
Terminal Specification N/A Bus Bar Type
Neutral Protection N/A
Note N/A Special Order Item.
Line/Load Lug type breakers can be converted to busbar connection type. Consult Sales for details

2 pole mechanism in a 3 pole frame.
N/A Special Order Item.
Line/Load Lug type breakers can be converted to busbar connection type. Consult Sales for details

2 pole mechanism in a 3 pole frame.
N/A Special Order Item.
Line/Load Lug type breakers can be converted to busbar connection type. Consult Sales for details

2 pole mechanism in a 3 pole frame.
N/A Special Order Item.
Line/Load Lug type breakers can be converted to busbar connection type. Consult Sales for details.
N/A Special Order Item.
Line/Load Lug type breakers can be converted to busbar connection type. Consult Sales for details.
Features N/A
  • High-breaking capacity and a patented arc extinguishing design
  • Bearing-type spindle reduces the operating force required to open and close the operating mechanism
  • High quality compact modular design
  • Fixed and adjustable trip unit settings
  • Line and load lugs installed standard
Certifications N/A
  • UL 489 Listed, File Number E355392
  • CSA Standards 22.2 No.5 File Number E355392
  • IEC/EN 60947-2
  • CE Compliant
  • RoHS Compliant
N/A
  • UL 489 Listed, File Number E355392
  • CSA Standards 22.2 No.5 File Number E355392
  • IEC/EN 60947-2
  • CE Compliant
  • RoHS Compliant
N/A
  • UL 489 Listed, File Number E355392
  • CSA Standards 22.2 No.5 File Number E355392
  • IEC/EN 60947-2
  • CE Compliant
  • RoHS Compliant
N/A
  • UL 489 Listed, File Number E355392
  • CSA Standards 22.2 No.5 File Number E355392
  • IEC/EN 60947-2
  • CE Compliant
  • RoHS Compliant
N/A
  • UL 489 Listed, File Number E355392
  • CSA Standards 22.2 No.5 File Number E355392
  • IEC/EN 60947-2
  • CE Compliant
  • RoHS Compliant
UL Certificate N/A Ex9 Series M5 Bus Bar and Lug Line/Load Side Connection Molded Case Circuit Breakers (NOA_M5_UL Certificate)
PDF - 2D CAD Drawings N/A
Description N/A 600A - M5S Busbar Connection; 2 Poles;
Adjustable Thermal and Adjustable Magnetic, MCCB
N/A 700A - M5S Busbar Connection; 2 Poles;
Adjustable Thermal and Adjustable Magnetic, MCCB
N/A 800A - M5S Busbar Connection; 2 Poles;
Adjustable Thermal and Adjustable Magnetic, MCCB
N/A 600A - M5S Busbar Connection; 3 Poles;
Adjustable Thermal and Adjustable Magnetic, MCCB
N/A 700A - M5S Busbar Connection; 3 Poles;
Adjustable Thermal and Adjustable Magnetic, MCCB