Molded Case Switches, 100-1200 Amperes

NOARK® Electric offers a complete range of UL 489 listed Molded Case Switches in six frame sizes: M1 - 150 A, M2 - 250 A, M3 - 400 A, M4 - 600 A, M5 - 800 A, and M6 - 1200 A. Each frame size offers a range of interrupting ratings at 240-690 Vac and 250-600 Vdc. Molded Case Switches are only used as disconnect switches. 5-Year limited warranty.
Unit of Measure
Items
Ex9 Series M4D Bus Bar, Lug Line/Load Side, Rear, and Draw-Out Connection Molded Case Switches

Ex9 Series M4D Bus Bar Connection 2 Poles Molded Case Switch
BOM

Ex9 Series M4D Bus Bar, Lug Line/Load Side, Rear, and Draw-Out Connection Molded Case Switches

Ex9 Series M4D Lug Line/Load Side Connection 2 Poles Molded Case Switch
BOM

Ex9 Series M4D Bus Bar, Lug Line/Load Side, Rear, and Draw-Out Connection Molded Case Switches

Ex9 Series M4D Bus Bar Connection 3 Poles Molded Case Switch
BOM

Ex9 Series M4D Bus Bar, Lug Line/Load Side, Rear, and Draw-Out Connection Molded Case Switches

Ex9 Series M4D Lug Line/Load Side Connection 3 Poles Molded Case Switch
BOM

Ex9 Series M4D Bus Bar, Lug Line/Load Side, Rear, and Draw-Out Connection Molded Case Switches

Ex9 Series M4DH Bus Bar Connection 2 Poles Molded Case Switch
BOM
Description N/A Molded Case Switches, 100-1200 Amperes

NOARK® Electric offers a complete range of UL 489 listed Molded Case Switches in six frame sizes: M1 - 150 A, M2 - 250 A, M3 - 400 A, M4 - 600 A, M5 - 800 A, and M6 - 1200 A. Each frame size offers a range of interrupting ratings at 240-690 Vac and 250-600 Vdc. Molded Case Switches are only used as disconnect switches. 5-Year limited warranty.
Brands N/A
Rated Current N/A 600 A
Rated Current at 480 Alternating Current (AC) Voltage N/A
Number of Poles N/A 2 N/A 2 N/A 3 N/A 3 N/A 2
Connection Type N/A Bus Bar Connection N/A Lug Line/Load Side Connection N/A Bus Bar Connection N/A Lug Line/Load Side Connection N/A Bus Bar Connection
Certifications N/A
  • UL 489 Listed Recognized, File Number E355396 (Standard for connection terminals which allows the user to apply field wiring directly to the breaker)
  • Certified for Canada According to CSA Standards 22.2 No.5
  • IEC/EN 60947-2
  • CE Compliant
  • RoHS Compliant
Features N/A
  • Instantaneous trip ability and a patented arc extinguishing design
  • Bearing-type spindle reduces the operating force required to open and close the operating mechanism
  • High-quality compact modular design
Note N/A Bus Bar Connection MCS not sold with (Bus Bar Connection not available through NOARK® Electric) or Terminal Lugs. N/A Lug Line/Load Side Connection MCS sold with Terminal Lugs N/A Bus Bar Connection MCS not sold with (Bus Bar Connection not available through NOARK® Electric) or Terminal Lugs. N/A Lug Line/Load Side Connection MCS sold with Terminal Lugs N/A Bus Bar Connection MCS not sold with (Bus Bar Connection not available through NOARK® Electric) or Terminal Lugs.