NOARK® Electric offers a complete range of 3 pole Molded Case Motor Circuit Protectors (MCPs, magnetic or short circuit protection only) which are used to protect the cables feeding three phase motors in six frame sizes: M1M - 150 A, M2M - 250 A, M3M - 400 A, M4M - 600 A, M5M - 800 A, and M6M - 1200 A. Each frame size offers a range of interrupting ratings at 240-690 Vac and 250-600 Vdc. 5-Year limited warranty.
Unit of Measure
Items
Ex9 Series M2M, S Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector (M2MS250T3)

Ex9 Series M2M, S Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector
BOM

Ex9 Series M2M, S Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector (M2MS250T3)

Ex9 Series M2M, N Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector
BOM

Ex9 Series M1M, 3 Ampere (A) Continuous Current H Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector

Ex9 Series M2M, H Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector
BOM

Ex9 Series M1M, 3 Ampere (A) Continuous Current H Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector

Ex9 Series M2M, S Interrupting - Lug Line/Load Side Connection Molded Case Motor Circuit Protector
BOM

Ex9 Series M1M, 3 Ampere (A) Continuous Current H Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector

Ex9 Series M2M, N Interrupting - Lug Line/Load Side Connection Molded Case Motor Circuit Protector
BOM
Description N/A NOARK® Electric offers a complete range of 3 pole Molded Case Motor Circuit Protectors (MCPs, magnetic or short circuit protection only) which are used to protect the cables feeding three phase motors in six frame sizes: M1M - 150 A, M2M - 250 A, M3M - 400 A, M4M - 600 A, M5M - 800 A, and M6M - 1200 A. Each frame size offers a range of interrupting ratings at 240-690 Vac and 250-600 Vdc. 5-Year limited warranty.
Brands N/A NOARK®
Continuous Current N/A 250 A
Cam Setting N/A A B C D E F G
Full Load Current at Cam Setting A N/A 96.2 to 115.3 A
Full Load Current at Cam Setting B N/A 115.4 to 134.5 A
Full Load Current at Cam Setting C N/A 134.6 to 153.7 A
Full Load Current at Cam Setting D N/A 153.8 to 173.0 A
Full Load Current at Cam Setting E N/A 173.1 to 192.2 A
Full Load Current at Cam Setting F N/A 192.3 to 211.4 A
Full Load Current at Cam Setting G N/A 211.5 to 217.6 A
Motor Circuit Protection (MCP) Trip Setting  at Cam Setting A N/A 1250
Motor Circuit Protection (MCP) Trip Setting  at Cam Setting B N/A 1500
Motor Circuit Protection (MCP) Trip Setting  at Cam Setting C N/A 1750
Motor Circuit Protection (MCP) Trip Setting  at Cam Setting D N/A 2000
Motor Circuit Protection (MCP) Trip Setting  at Cam Setting E N/A 2250
Motor Circuit Protection (MCP) Trip Setting  at Cam Setting F N/A 2500
Motor Circuit Protection (MCP) Trip Setting  at Cam Setting G N/A 2750
Rated Current at 480 Alternating Current (AC) Voltage N/A 35 kA N/A 65 kA N/A 100 kA N/A 35 kA N/A 65 kA
Connection Type N/A S Interrupting - Bus Bar Connection N/A N Interrupting - Bus Bar Connection N/A H Interrupting - Bus Bar Connection N/A S Interrupting - Lug Line/Load Side Connection N/A N Interrupting - Lug Line/Load Side Connection
Features N/A The traditional system used for this purpose is based on three different devices: a circuit breaker for protection against short-circuit, a thermal relay for protection against overload and phase loss or unbalance of phase, and a contactor for motor switching.
In particular, when selecting these devices, different factors must be taken into consideration, such as:
  • The motor power
  • The diagram and type of starting
  • The type of motor: with cage rotor or with wound rotor
  • The fault current at the point of the network where the motor is installed
Certifications N/A
  • UL 489 Recognized, File Number E355392 (Standard for connection terminals which allows the user to apply field wiring directly to the breaker)
  • Certified for Canada According to CSA Standards 22.2 No.5
  • IEC/EN 60947-2
  • CE Compliant
  • RoHS Compliant
Note N/A Bus Bar Connection MCP not sold with (Bus Bar Connection not available through NOARK® Electric) or Terminal Lugs. N/A Bus Bar Connection MCP not sold with (Bus Bar Connection not available through NOARK® Electric) or Terminal Lugs. N/A Bus Bar Connection MCP not sold with (Bus Bar Connection not available through NOARK® Electric) or Terminal Lugs. N/A Lug Line/Load Side Connection MCP sold with Terminal Lugs. N/A Lug Line/Load Side Connection MCP sold with Terminal Lugs.