Ex9CA Series Safety Contactors
Safety Contactors and Relays
The NOARK® Ex9CA Safety Contactor is designed for use in safety function applications. It offers special features that allow the design of safe control circuits with current ratings up to 38 Amps.
The Normally Closed (NC) Auxiliary contact is a mirror contact to the main contacts and is mechanically linked to the Normally Open (NO) Auxiliary contacts. This allows for optimal design selections in SRP/CS (SRP/CS is the term given by ISO short for safety-related part of a control system, meaning part of a control system that responds to safety-related input signals and generates safety-related output signals.). 5-Year limited warranty.
The Normally Closed (NC) Auxiliary contact is a mirror contact to the main contacts and is mechanically linked to the Normally Open (NO) Auxiliary contacts. This allows for optimal design selections in SRP/CS (SRP/CS is the term given by ISO short for safety-related part of a control system, meaning part of a control system that responds to safety-related input signals and generates safety-related output signals.). 5-Year limited warranty.
Unit of Measure
Items |
/Asset/Ex9CA1822---right.jpg Ex9CA0911B7 Ex9CA Series 24 Volt (V) Alternating Current (AC) Voltage and 9 Ampere (A) Current Safety Contactor |
/Asset/Ex9CA1822---right.jpg Ex9CA0911E7 Ex9CA Series 48 Volt (V) Alternating Current (AC) Voltage and 9 Ampere (A) Current Safety Contactor |
/Asset/Ex9CA1822---right.jpg Ex9CA0911G7 Ex9CA Series 120 Volt (V) Alternating Current (AC) Voltage and 9 Ampere (A) Current Safety Contactor |
/Asset/Ex9CA1822---right.jpg Ex9CA0911U7 Ex9CA Series 240 Volt (V) Alternating Current (AC) Voltage and 9 Ampere (A) Current Safety Contactor |
/Asset/Ex9CA1822---right.jpg Ex9CA09D11B Ex9CA Series 24 Volt (V) Direct Current (DC) Voltage and 9 Ampere (A) Current Safety Contactor |
|||||
Description |
N/A
The NOARK® Ex9CA Safety Contactor is designed for use in safety function applications. It offers special features that allow the design of safe control circuits with current ratings up to 38 Amps. The Normally Closed (NC) Auxiliary contact is a mirror contact to the main contacts and is mechanically linked to the Normally Open (NO) Auxiliary contacts. This allows for optimal design selections in SRP/CS (SRP/CS is the term given by ISO short for safety-related part of a control system, meaning part of a control system that responds to safety-related input signals and generates safety-related output signals.). 5-Year limited warranty. |
|||||||||
Brands | N/A NOARK® | |||||||||
Contacts | N/A 1 Normally Open (NO) + 1 Normally Closed (NC) | |||||||||
Alternating Current (AC) Voltage | N/A 24 V | N/A 48 V | N/A 120 V | N/A 240 V | N/A | |||||
Direct Current (DC) Voltage | N/A | N/A | N/A | N/A | N/A 24 V | |||||
Current | N/A 9 A | |||||||||
Limited Warranty | N/A 5 years | |||||||||
Certifications |
N/A
|
|||||||||
Features |
N/A
|
|||||||||
|