Breaker Frame Selection:
Use the filters below to find the correct Breaker or Switch Frame for your application. For Drawout Version, Cassette is included with Frame selection.
Click BOM to add it to the printable bill-of-material.




Use these links to proceed to the selection of required Accessories and Trip Units.

GO TO Select Trip Unit GO TO Select Accessories BACK to Selection Categories

 

A32-3200A-Drawout Front4.png
Unit of Measure
Items A32-3200A-Drawout Front4.png
A32H3DH1600
1600A, 100kA, 3 Pole, Drawout, Horizontal Terminal Adapters, Circuit Breaker
A32-3200A-Drawout Front4.png
A32H3DH2000
2000A, 100kA, 3 Pole, Drawout, Horizontal Terminal Adapters, Circuit Breaker
A32-3200A-Drawout Front4.png
A32H3DH2500
2500A, 100kA, 3 Pole, Drawout, Horizontal Terminal Adapters, Circuit Breaker
A32-3200A-Drawout Front4.png
A32H3DH800
800A, 100kA, 3 Pole, Drawout, Horizontal Terminal Adapters, Circuit Breaker
A32-3200A-Drawout Front4.png
A32H3DV1600
1600A, 100kA, 3 Pole, Drawout, Vertical Terminal Adapters, Circuit Breaker
Frame Type N/A Circuit Breaker
Features N/A
  • 800A through 3200A Draw Out
  • 800A through 2500A Fixed
  • IC ratings up to 100kA at 635V
  • Short-Time Withstand, 100kA at 635V
  • 50 or 60 HZ operation
  • 3 Pole and 4 Pole designs
  • 10,000 Operations, before maintenance (Mechanical)
  • 6,000 Operations, before maintenance (Electrical)
N/A
  • 800A through 3200A Draw Out
  • 800A through 2500A Fixed
  • IC ratings up to 100kA at 635V
  • Short-Time Withstand, 100kA at 635V
  • 50 or 60 HZ operation
  • 3 Pole and 4 Pole designs
  • 10,000 Operations, before maintenance (Mechanical)
  • 6,000 Operations, before maintenance (Electrical)
N/A
  • 800A through 3200A Draw Out
  • 800A through 2500A Fixed
  • IC ratings up to 100kA at 635V
  • Short-Time Withstand, 100kA at 635V
  • 50 or 60 HZ operation
  • 3 Pole and 4 Pole designs
  • 10,000 Operations, before maintenance (Mechanical)
  • 6,000 Operations, before maintenance (Electrical)
N/A
  • 800A through 3200A Draw Out
  • 800A through 2500A Fixed
  • IC ratings up to 100kA at 635V
  • Short-Time Withstand, 100kA at 635V
  • 50 or 60 HZ operation
  • 3 Pole and 4 Pole designs
  • 10,000 Operations, before maintenance (Mechanical)
  • 6,000 Operations, before maintenance (Electrical)
N/A
  • 800A through 3200A Draw Out
  • 800A through 2500A Fixed
  • IC ratings up to 100kA at 635V
  • Short-Time Withstand, 100kA at 635V
  • 50 or 60 HZ operation
  • 3 Pole and 4 Pole designs
  • 10,000 Operations, before maintenance (Mechanical)
  • 6,000 Operations, before maintenance (Electrical)
Rated Current N/A 1600 A N/A 2000 A N/A 2500 A N/A 800 A N/A 1600 A
Interrupting Capacity or Withstand Rating (kA) N/A 100 kA
Number of Poles N/A 3
Mounting Type N/A Drawout
Terminal Orientation N/A Per Cassette
Overall Dimensions N/A 16.93 (H) x 17.20 (W) x 17.05 (D) in
Minimum Enclosure Dimensions N/A 21.65 (H) x 23.62 (W) x 18.11 (D) in
Certifications N/A
  • UL 1066, Low-Voltage AC and DC Power Circuit Breakers
  • CSA C22.2 No. 31
  • ANSI C37.13 Low Voltage Power Circuit Breakers
  • ANSI C37.16 Low Voltage Power Circuit Breakers, Ratings, Related Requirements and Applications
  • ANSI C37.50 - Low Voltage AC Power Circuit Breakers, Test Procedure
  • ANSI C37.17 - IEEE Standard for Trip Systems
N/A
  • UL 1066, Low-Voltage AC and DC Power Circuit Breakers
  • CSA C22.2 No. 31
  • ANSI C37.13 Low Voltage Power Circuit Breakers
  • ANSI C37.16 Low Voltage Power Circuit Breakers, Ratings, Related Requirements and Applications
  • ANSI C37.50 - Low Voltage AC Power Circuit Breakers, Test Procedure
  • ANSI C37.17 - IEEE Standard for Trip Systems
N/A
  • UL 1066, Low-Voltage AC and DC Power Circuit Breakers
  • CSA C22.2 No. 31
  • ANSI C37.13 Low Voltage Power Circuit Breakers
  • ANSI C37.16 Low Voltage Power Circuit Breakers, Ratings, Related Requirements and Applications
  • ANSI C37.50 - Low Voltage AC Power Circuit Breakers, Test Procedure
  • ANSI C37.17 - IEEE Standard for Trip Systems
N/A
  • UL 1066, Low-Voltage AC and DC Power Circuit Breakers
  • CSA C22.2 No. 31
  • ANSI C37.13 Low Voltage Power Circuit Breakers
  • ANSI C37.16 Low Voltage Power Circuit Breakers, Ratings, Related Requirements and Applications
  • ANSI C37.50 - Low Voltage AC Power Circuit Breakers, Test Procedure
  • ANSI C37.17 - IEEE Standard for Trip Systems
N/A
  • UL 1066, Low-Voltage AC and DC Power Circuit Breakers
  • CSA C22.2 No. 31
  • ANSI C37.13 Low Voltage Power Circuit Breakers
  • ANSI C37.16 Low Voltage Power Circuit Breakers, Ratings, Related Requirements and Applications
  • ANSI C37.50 - Low Voltage AC Power Circuit Breakers, Test Procedure
  • ANSI C37.17 - IEEE Standard for Trip Systems