NOARK® Electric Molded Case Circuit Breakers Ex9M6 Series:
- UL 489 Listed, File Number E35539
- CSA Standards 22.2 No.5 File Number E355392
- 800A to 1200A Ratings
- 600VAC Maximum
- 3 Pole, 4 Pole
- Electronic Trip Unit (LI, LSI, LSIG)

  Interrupting Ratings:
  Ex9M6S Ex9M6N
  65kAIC at 240VAC 100kAIC at 240VAC
  42kAIC at 480Vac 65kAIC at 480VAC
  22kAIC at 600VAC 42kAIC at 600VAC
Ex9 Series M6 Bus Bar and Lug Line/Load Side Connection Molded Case Circuit Breakers
Items M6 3P4W-Front
M6S800E3W4
Ex9M6S Series MCCB; Electronic Trip Unit
M6 3P4W-Front
M6S1000E3W4
Ex9M6S Series MCCB; Electronic Trip Unit
M6 3P4W-Front
M6S1200E3W4
Ex9M6S Series MCCB; Electronic Trip Unit
Ex9 Series M6 Bus Bar and Lug Line/Load Side Connection Molded Case Circuit Breakers
M6S800E4
Ex9M6S Series MCCB; Electronic Trip Unit
Ex9 Series M6 Bus Bar and Lug Line/Load Side Connection Molded Case Circuit Breakers
M6S1000E4
Ex9M6S Series MCCB; Electronic Trip Unit
Rated Current N/A 800 A N/A 1000 A N/A 1200 A N/A 800 A N/A 1000 A
Number of Poles N/A 3 N/A 3 N/A 3 N/A 4 N/A 4
Description N/A

1200A Frame Size MCCB, 800A, 3P, 42kA@480Vac, Electronic Trip Unit 3P4W, Bus bar connection, 80% Rated

N/A

1200A Frame Size MCCB, 1000A, 3P, 42kA@480Vac, Electronic Trip Unit 3P4W, Bus bar connection, 80% Rated

N/A

1200A Frame Size MCCB, 1200A, 3P, 42kA@480Vac, Electronic Trip Unit 3P4W, Bus bar connection, 80% Rated

N/A 800A - M6S Busbar Connection; 4 Poles; 80% Rated
Electronic Trip Unit, MCCB
N/A 1000A - M6S Busbar Connection; 4 Poles; 80% Rated
Electronic Trip Unit, MCCB
Brands N/A
Interrupting Capacity at 480VAC N/A 42 kA N/A 42 kA N/A 42 kA N/A 65 kA N/A 65 kA
Rate Code N/A 80 %
Certifications N/A
  • UL 489 Listed, File Number E355392
  • CSA Standards 22.2 No.5 File Number E355392
  • IEC/EN 60947-2
  • CE Compliant
  • RoHS Compliant
N/A
  • UL 489 Listed, File Number E355392
  • CSA Standards 22.2 No.5 File Number E355392
  • IEC/EN 60947-2
  • CE Compliant
  • RoHS Compliant
N/A
  • UL 489 Listed, File Number E355392
  • CSA Standards 22.2 No.5 File Number E355392
  • IEC/EN 60947-2
  • CE Compliant
  • RoHS Compliant
N/A
  • UL 489 Listed, File Number E355392
  • CSA Standards 22.2 No.5 File Number E355392
  • IEC/EN 60947-2
  • CE Compliant
  • RoHS Compliant
N/A
  • UL 489 Listed, File Number E355392
  • CSA Standards 22.2 No.5 File Number E355392
  • IEC/EN 60947-2
  • CE Compliant
  • RoHS Compliant
IC Class N/A S
Interrupting Capacity N/A 42kA at 480Vac N/A 42kA at 480Vac N/A 42kA at 480Vac N/A 22kA at 600Vac 42kA at 480Vac 65kA at 240Vac N/A 22kA at 600Vac 42kA at 480Vac 65kA at 240Vac
Termination Type N/A Bus Bar Connection
Features N/A
  • High-breaking capacity and a patented arc extinguishing design
  • Bearing-type spindle reduces the operating force required to open and close the operating mechanism
  • High quality compact modular design
  • Fixed and adjustable trip unit settings
  • Line and load lugs installed standard
N/A
  • High-breaking capacity and a patented arc extinguishing design
  • Bearing-type spindle reduces the operating force required to open and close the operating mechanism
  • High quality compact modular design
  • Fixed and adjustable trip unit settings
  • Line and load lugs installed standard
N/A
  • High-breaking capacity and a patented arc extinguishing design
  • Bearing-type spindle reduces the operating force required to open and close the operating mechanism
  • High quality compact modular design
  • Fixed and adjustable trip unit settings
  • Line and load lugs installed standard
N/A
  • High-breaking capacity and a patented arc extinguishing design
  • Bearing-type spindle reduces the operating force required to open and close the operating mechanism
  • High quality compact modular design
  • Fixed and adjustable trip unit settings
  • Line and load lugs installed standard
N/A
  • High-breaking capacity and a patented arc extinguishing design
  • Bearing-type spindle reduces the operating force required to open and close the operating mechanism
  • High quality compact modular design
  • Fixed and adjustable trip unit settings
  • Line and load lugs installed standard
Note N/A

Bus Bar Connection MCCB not sold with Bus Bar or Terminal Lugs.

N/A

Bus Bar Connection MCCB not sold with Bus Bar or Terminal Lugs.

N/A

Bus Bar Connection MCCB not sold with Bus Bar or Terminal Lugs.

N/A Bus Bar Connection MCCB not sold with Bus Bar or Terminal Lugs. N/A Bus Bar Connection MCCB not sold with Bus Bar or Terminal Lugs.
UL Certificate N/A Ex9 Series M6 3 Poles 4 Wire Bus Bar and Lug Line/Load Side Connection Molded Case Circuit Breakers (NOA_M6_3P4W_UL Certificate)
N/A Ex9 Series M6 3 Poles 4 Wire Bus Bar and Lug Line/Load Side Connection Molded Case Circuit Breakers (NOA_M6_3P4W_UL Certificate)
N/A Ex9 Series M6 3 Poles 4 Wire Bus Bar and Lug Line/Load Side Connection Molded Case Circuit Breakers (NOA_M6_3P4W_UL Certificate)
N/A Ex9 Series M6 Bus Bar and Lug Line/Load Side Connection Molded Case Circuit Breakers (NOA_M6_UL Certificate)
N/A Ex9 Series M6 Bus Bar and Lug Line/Load Side Connection Molded Case Circuit Breakers (NOA_M6_UL Certificate)
Terminal Specification N/A Bus Bar Type