Items |
M5MS800T3 Ex9 Series M5M, S Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector |
M5MN800T3 Ex9 Series M5M, N Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector |
M5MH800T3 Ex9 Series M5M, H Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector |
M5MS800T3L Ex9 Series M5M, S Interrupting - Lug Line/Load Side Connection Molded Case Motor Circuit Protector |
M5MN800T3L Ex9 Series M5M, N Interrupting - Lug Line/Load Side Connection Molded Case Motor Circuit Protector |
|||||
Description | N/A NOARK® Electric offers a complete range of 3 pole Molded Case Motor Circuit Protectors (MCPs, magnetic or short circuit protection only) which are used to protect the cables feeding three phase motors in six frame sizes: M1M - 150 A, M2M - 250 A, M3M - 400 A, M4M - 600 A, M5M - 800 A, and M6M - 1200 A. Each frame size offers a range of interrupting ratings at 240-690 Vac and 250-600 Vdc. 5-Year limited warranty. | |||||||||
Brands | N/A NOARK® | |||||||||
Continuous Current | N/A 800 A | |||||||||
Cam Setting | N/A A B C D E F G | |||||||||
Full Load Current at Cam Setting A | N/A 307.7 to 369.1 A | |||||||||
Full Load Current at Cam Setting B | N/A 369.2 to 430.7 A | |||||||||
Full Load Current at Cam Setting C | N/A 430.8 to 492.2 A | |||||||||
Full Load Current at Cam Setting D | N/A 492.3 to 553.7 A | |||||||||
Full Load Current at Cam Setting E | N/A 553.8 to 615.3 A | |||||||||
Full Load Current at Cam Setting F | N/A 615.4 to 676.8 A | |||||||||
Full Load Current at Cam Setting G | N/A 676.9 to 738.5 A | |||||||||
Motor Circuit Protection (MCP) Trip Setting at Cam Setting A | N/A 4000 | |||||||||
Motor Circuit Protection (MCP) Trip Setting at Cam Setting B | N/A 4800 | |||||||||
Motor Circuit Protection (MCP) Trip Setting at Cam Setting C | N/A 5600 | |||||||||
Motor Circuit Protection (MCP) Trip Setting at Cam Setting D | N/A 6400 | |||||||||
Motor Circuit Protection (MCP) Trip Setting at Cam Setting E | N/A 7200 | |||||||||
Motor Circuit Protection (MCP) Trip Setting at Cam Setting F | N/A 8000 | |||||||||
Motor Circuit Protection (MCP) Trip Setting at Cam Setting G | N/A 8800 | |||||||||
Rated Current at 480 Alternating Current (AC) Voltage | N/A 42 kA | N/A 65 kA | N/A 100 kA | N/A 42 kA | N/A 65 kA | |||||
Connection Type | N/A S Interrupting - Bus Bar Connection | N/A N Interrupting - Bus Bar Connection | N/A H Interrupting - Bus Bar Connection | N/A S Interrupting - Lug Line/Load Side Connection | N/A N Interrupting - Lug Line/Load Side Connection | |||||
Features |
N/A
The traditional system used for this purpose is based on three different devices: a circuit breaker for protection against short-circuit, a thermal relay for protection against overload and phase loss or unbalance of phase, and a contactor for motor switching. In particular, when selecting these devices, different factors must be taken into consideration, such as:
|
|||||||||
Certifications |
N/A
|
|||||||||
Note | N/A Bus Bar Connection MCP not sold with (Bus Bar Connection not available through NOARK® Electric) or Terminal Lugs. | N/A Bus Bar Connection MCP not sold with (Bus Bar Connection not available through NOARK® Electric) or Terminal Lugs. | N/A Bus Bar Connection MCP not sold with (Bus Bar Connection not available through NOARK® Electric) or Terminal Lugs. | N/A Lug Line/Load Side Connection MCP sold with Terminal Lugs. | N/A Lug Line/Load Side Connection MCP sold with Terminal Lugs. | |||||
|