Ex9M1M 3 to 150A Motor Circuit Protectors
Motor-Circuit Protectors
NOARK® Electric offers a complete range of 3 pole Molded Case Motor Circuit Protectors (MCPs, magnetic or short circuit protection only) which are used to protect the cables feeding three phase motors in six frame sizes: M1M - 150 A, M2M - 250 A, M3M - 400 A, M4M - 600 A, M5M - 800 A, and M6M - 1200 A. Each frame size offers a range of interrupting ratings at 240-690 Vac and 250-600 Vdc. 5-Year limited warranty.
1 2
Clear
Filter
Continuous Current (A)
Full Load Current at Cam Setting A (A)
Full Load Current at Cam Setting B (A)
Connection Type
Catalog Number |
Item Name |
Continuous Current |
Full Load Current at Cam Setting A |
Motor Circuit Protection (MCP) Trip Setting at Cam Setting A |
Add to Bill of Materials |
---|---|---|---|---|---|
M1MS03T3 /Asset/a1183.jpg | N/A Ex9 Series M1M, 3 Ampere (A) Continuous Current S Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 3 A | Full Load Current at Cam Setting A N/A 1.6 to 1.7 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 21 | BOM |
M1MS07T3 /Asset/a1183.jpg | N/A Ex9 Series M1M, 7 Ampere (A) Continuous Current S Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 7 A | Full Load Current at Cam Setting A N/A 2.7 to 3.1 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 35 | BOM |
M1MS15T3 /Asset/a1183.jpg | N/A Ex9 Series M1M, 15 Ampere (A) Continuous Current S Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 15 A | Full Load Current at Cam Setting A N/A 5.7 to 6.8 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 75 | BOM |
M1MS30T3 /Asset/a1183.jpg | N/A Ex9 Series M1M, 30 Ampere (A) Continuous Current S Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 30 A | Full Load Current at Cam Setting A N/A 11.5 to 13.7 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 150 | BOM |
M1MS50T3 /Asset/a1183.jpg | N/A Ex9 Series M1M, 50 Ampere (A) Continuous Current S Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 50 A | Full Load Current at Cam Setting A N/A 19.2 to 22.9 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 250 | BOM |
M1MS70T3 /Asset/a1183.jpg | N/A Ex9 Series M1M, 70 Ampere (A) Continuous Current S Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 70 A | Full Load Current at Cam Setting A N/A 26.9 to 32.2 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 350 | BOM |
M1MS100T3 /Asset/a1183.jpg | N/A Ex9 Series M1M, 100 Ampere (A) Continuous Current S Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 100 A | Full Load Current at Cam Setting A N/A 38.4 to 46.0 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 500 | BOM |
M1MS150T3 /Asset/a1183.jpg | N/A Ex9 Series M1M, 150 Ampere (A) Continuous Current S Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 150 A | Full Load Current at Cam Setting A N/A 57.7 to 69.1 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 750 | BOM |
M1MN03T3 /Asset/a1183.jpg | N/A Ex9 Series M1M, 3 Ampere (A) Continuous Current N Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 3 A | Full Load Current at Cam Setting A N/A 1.6 to 1.7 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 21 | BOM |
M1MN07T3 /Asset/a1183.jpg | N/A Ex9 Series M1M, 7 Ampere (A) Continuous Current N Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 7 A | Full Load Current at Cam Setting A N/A 2.7 to 3.1 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 35 | BOM |
M1MN15T3 /Asset/a1183.jpg | N/A Ex9 Series M1M, 15 Ampere (A) Continuous Current N Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 15 A | Full Load Current at Cam Setting A N/A 5.7 to 6.8 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 75 | BOM |
M1MN30T3 /Asset/a1183.jpg | N/A Ex9 Series M1M, 30 Ampere (A) Continuous Current N Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 30 A | Full Load Current at Cam Setting A N/A 11.5 to 13.7 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 150 | BOM |
M1MN50T3 /Asset/a1183.jpg | N/A Ex9 Series M1M, 50 Ampere (A) Continuous Current N Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 50 A | Full Load Current at Cam Setting A N/A 19.2 to 22.9 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 250 | BOM |
M1MN70T3 /Asset/a1183.jpg | N/A Ex9 Series M1M, 70 Ampere (A) Continuous Current N Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 70 A | Full Load Current at Cam Setting A N/A 26.9 to 32.2 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 350 | BOM |
M1MN100T3 /Asset/a1183.jpg | N/A Ex9 Series M1M, 100 Ampere (A) Continuous Current N Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 100 A | Full Load Current at Cam Setting A N/A 38.4 to 46.0 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 500 | BOM |
M1MN150T3 /Asset/a1183.jpg | N/A Ex9 Series M1M, 150 Ampere (A) Continuous Current N Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 150 A | Full Load Current at Cam Setting A N/A 57.7 to 69.1 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 750 | BOM |
M1MH03T3 /Asset/MCP---face.jpg | N/A Ex9 Series M1M, 3 Ampere (A) Continuous Current H Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 3 A | Full Load Current at Cam Setting A N/A 1.6 to 1.7 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 21 | BOM |
M1MH07T3 /Asset/MCP---face.jpg | N/A Ex9 Series M1M, 7 Ampere (A) Continuous Current H Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 7 A | Full Load Current at Cam Setting A N/A 2.7 to 3.1 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 35 | BOM |
M1MH15T3 /Asset/MCP---face.jpg | N/A Ex9 Series M1M, 15 Ampere (A) Continuous Current H Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 15 A | Full Load Current at Cam Setting A N/A 5.7 to 6.8 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 75 | BOM |
M1MH30T3 /Asset/MCP---face.jpg | N/A Ex9 Series M1M, 30 Ampere (A) Continuous Current H Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 30 A | Full Load Current at Cam Setting A N/A 11.5 to 13.7 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 150 | BOM |
M1MH50T3 /Asset/MCP---face.jpg | N/A Ex9 Series M1M, 50 Ampere (A) Continuous Current H Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 50 A | Full Load Current at Cam Setting A N/A 19.2 to 22.9 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 250 | BOM |
M1MH70T3 /Asset/MCP---face.jpg | N/A Ex9 Series M1M, 70 Ampere (A) Continuous Current H Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 70 A | Full Load Current at Cam Setting A N/A 26.9 to 32.2 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 350 | BOM |
M1MH100T3 /Asset/MCP---face.jpg | N/A Ex9 Series M1M, 100 Ampere (A) Continuous Current H Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 100 A | Full Load Current at Cam Setting A N/A 38.4 to 46.0 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 500 | BOM |
M1MH150T3 /Asset/MCP---face.jpg | N/A Ex9 Series M1M, 150 Ampere (A) Continuous Current H Interrupting - Bus Bar Connection Molded Case Motor Circuit Protector | Continuous Current N/A 150 A | Full Load Current at Cam Setting A N/A 57.7 to 69.1 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 750 | BOM |
M1MS03T3L /Asset/a1186.jpg | N/A Ex9 Series M1M, 3 Ampere (A) Continuous Current S Interrupting - Lug Line/Load Side Connection Molded Case Motor Circuit Protector | Continuous Current N/A 3 A | Full Load Current at Cam Setting A N/A 1.6 to 1.7 A | Motor Circuit Protection (MCP) Trip Setting at Cam Setting A N/A 21 | BOM |